電控消防水炮遙控器性能有哪些測試要求
在電控消防水炮滅火(huo)系統(tong)(tong)中,需(xu)要(yao)配套無線遙控器使(shi)用,它也是保(bao)證現(xian)(xian)(xian)(xian)場工作(zuo)人員安(an)全的有力保(bao)障(zhang),比如(ru)說(shuo)現(xian)(xian)(xian)(xian)場發(fa)生火(huo)災時,由于現(xian)(xian)(xian)(xian)場控制(zhi)箱安(an)裝(zhuang)在被保(bao)護(hu)現(xian)(xian)(xian)(xian)場附近(jin),這個時候(hou)通過現(xian)(xian)(xian)(xian)場控制(zhi)箱來(lai)操作(zuo)水炮滅火(huo),人員的安(an)全系數低。而如(ru)果通過無線遙控器,就(jiu)可以在遠距(ju)離的地方(fang)操作(zuo)消防水炮進行(xing)滅火(huo),所以遙控器對于電控消防水炮系統(tong)(tong)來(lai)說(shuo)很重(zhong)要(yao)。

在規范《消(xiao)防(fang)炮》 GB19156-2019中,第6.8 遠(yuan)控消(xiao)防(fang)炮性(xing)能(neng)試(shi)(shi)驗章節提到了關于無線遙控器需(xu)要進(jin)行的性(xing)能(neng)測(ce)試(shi)(shi)項目(mu),主要包含(han)以下3點(dian):
6.8.1.1 響(xiang)應時間試驗
用無(wu)線遙控(kong)(kong)器或控(kong)(kong)制器分別操作(zuo)遠(yuan)控(kong)(kong)消防(fang)(fang)炮(pao)動(dong)(dong)作(zuo),用秒表測量從(cong)開始按下按鈕至消防(fang)(fang)炮(pao)開始動(dong)(dong)作(zuo)的時(shi)間,判(pan)斷(duan)試驗結果是否(fou)符合(he)5.8.1.1遠(yuan)控(kong)(kong)消防(fang)(fang)炮(pao)從(cong)無(wu)線遙控(kong)(kong)器或控(kong)(kong)制器啟動(dong)(dong)至消防(fang)(fang)炮(pao)動(dong)(dong)作(zuo)的響(xiang)應時(shi)間應小于5s的規(gui)定。
6.8.1.2 無(wu)線遙控距離試驗(yan)
在距(ju)遠控(kong)(kong)消(xiao)防炮(pao)150m處(chu),使用無線(xian)遙控(kong)(kong)器操(cao)作(zuo)遠控(kong)(kong)消(xiao)防炮(pao)動作(zuo),判斷試(shi)驗結果是否(fou)符合(he)5.8.1.2遠控(kong)(kong)消(xiao)防炮(pao)的無線(xian)遙控(kong)(kong)距(ju)離不應小(xiao)于150m的規定。
6.8.2.2 跌落試(shi)驗
將無線遙控(kong)器或手持式(shi)控(kong)制器以水平(ping)和(he)垂直的初始位置(zhi),從離(li)地(di)1.5m±0.1m的高(gao)處(從控(kong)制器最(zui)低點算起)自(zi)由落到混凝土地(di)面,以上述初始位置(zhi)分別墜落兩(liang)次(ci)后檢查遙控(kong)器性(xing)能,判斷試驗(yan)結果是(shi)否符合5.8.2.2無線遙控(kong)器應具(ju)有(you)抗跌落性(xing)能,進(jin)行跌落試驗(yan)后,應能正常工作的規定。
上述(shu)規(gui)范內容,不僅詳細介紹了電控消(xiao)防水炮(pao)遙控器(qi)的性(xing)能測試,而且還給出了結果(guo)需要符合的要求,所以準確性(xing)是有理可(ke)依(yi)的。